Whatever the need, be it a high volume urban wastewater treatment system or a specific application for a commercial development or industrial park August BioPro can provide the right treatment for the job.
AT biological reactors (hereinafter – bioreactors) are on-site aerobic continuous-flow wastewater treatment plants factory produced from extrusive polypropylene with active sludge for biological removal of organic pollutants (BDS and ChDS), nitrogen and phosphorus from household and industrial wastewater, which chemical compositions are similar.
| Type | Average daily flow
(m3/d) | Average daily load
(KG BDS5) | Dimensions of the Biological Reactor Diameter X Height (mm) | Number of Reactors | Sludge Production (m3/annum) | Average Energy Consumption kWH/d |
|---|---|---|---|---|---|---|
|
AT75
|
11.3
|
3.60
|
3300X3000
|
1
|
18.8
|
12.0
|
|
AT100
|
15.0
|
6.00
|
3500X3000
|
1
|
25.0
|
16.0
|
|
AT120
|
18.0
|
7.20
|
4000X3000
|
1
|
30.0
|
20.0
|
|
AT150
|
22.5
|
9.00
|
4500X3000
|
1
|
37.5
|
24.0
|
|
AT200
|
30.0
|
12.0
|
5000X3000
|
1
|
50.0
|
33.0
|
|
AT250
|
37.5
|
15.00
|
5300X3000
|
1
|
62.5
|
40.0
|
A bioreactor consists of anaerobic – anoxic, aeration zone and secondary sedimentation tank.
All zones are installed in a single horizontal repository of cylindrical shape and are separated by walls. By means of the airblower the excess sludge is removed into sludge stabilizer, which is mounted in a separate repository.
The treatment unit includes an air blower mounted next to the plant.
The shape, configuration, arrangement of treatment stages and equipment of bioreactors installed are analogous to all AT75 – AT250 models. Along with the increase in the capacity of bioreactors, the corresponding structural parameters of the equipment are increased.
Municipal VFL wastewater treatment plant AT300 – AT5000 is capable of servicing cities, towns with a large and small number of citizens: from several hundreds up to over five thousand citizens. Our project covers all levels of biological treatment and sludge sedimentation in the integrated reactor. It reduces the dimensions of the plant and simplifies construction works. The tankages of AT1000 – AT5000 bioreactors must be produced from reinforced concrete, whereas partitions can be installed from polypropylene.
| Type | V Average Daily Flow
(m3/d) | Average Daily Load
(KG BDS5) | Dimension of the Biological Reactor Diameter X Height (mm) | Number of Reactors | Sludge Production (m3/annum) | Average Energy Consumption kWH/d |
|---|---|---|---|---|---|---|
| AT300 | 45.0 | 18.0 | 4500X3000 | 2 | 75.0 | 48.0 |
| AT400 | 60.0 | 24.0 | 5000X3000 | 2 | 100.0 | 66.0 |
| AT500 | 75.0 | 30.0 | 5300X3000 | 2 | 125.0 | 80.0 |
| AT600 | 90.0 | 36.0 | 5000X3000 | 3 | 150.0 | 99.0 |
| AT750 | 112.5 | 45.0 | 5300X3000 | 3 | 187.5 | 120.0 |
VFL technology bioreactor contains integrated all levels of biological treatment and sludge sedimentation (anaerobic – anoxic, aeration zone and secondary sedimentation tank). All zones are installed in the aerotanks of rectangular shape, which base is made from concrete and partitions – from polypropylene.
LAs compared to the traditional treatment methods, VFL technology is superior to both space and energy efficiency. Treatment system is flexible as the duration of all treatment stages can be easily changed and adjusted. The treatment plants of this type are fitted for treatment of unequal and varying wastewater debits and loads.
| Type | Average Daily Flow(m3/d) | Average Daily Load (KG BDS5) | Dimensions of the Biological reactor Length X Width X Height
(mm) | Number of Reactors | Sludge Production KG/D | Average Energy Consumption kWH/d |
|---|---|---|---|---|---|---|
| AT1000 | 150.0 | 60.0 | 11X9X3.5 | 2 | 30.0 | 144.0 |
| AT1500 | 225.0 | 90.0 | 12X9X4.0 | 2 | 45.0 | 195.0 |
| AT2000 | 300.0 | 120.0 | 13X10X4.0 | 2 | 60.0 | 260.0 |
| AT2500 | 375.0 | 150.0 | 12X12X4.5 | 3 | 75.0 | 300 |
| AT3000 | 450.0 | 180.0 | 13X13X4.5 | 3 | 90.0 | 360.0 |
| AT3500 | 525.0 | 210.0 | 14X13X4.5 | 3 | 105.0 | 421.0 |
| AT4000 | 600.0 | 240.0 | 18X12X4.5 | 4 | 120.0 | 481.0 |
| AT4500 | 675.0 | 270.0 | 18X13X4.5 | 4 | 135.0 | 534.0 |
| AT5000 | 750.0 | 300.0 | 20X13X4.5 | 4 | 150.0 | 587.0 |
| Regular Treatment | High Treatment | ||||
|---|---|---|---|---|---|
| Parameter | Guaranteed Value | Average Value | Parameter | Guaranteed Value | Average Value |
|
ChDScr
|
75 mg/l
|
35 mg/l
|
ChDScr
|
50 mg/l
|
35 mg/l
|
|
BDS5
|
15 mg/l
|
10 mg/l
|
BDS5
|
7 mg/l
|
5 mg/l
|
|
SS
|
25 mg/l
|
15 mg/l
|
SS
|
10 mg/l
|
3 mg/l
|
|
N-NH4
|
2 mg/l
|
1 mg/l
|
N-NH4
|
2 mg/l
|
1 mg/l
|
|
Ntotal
|
30 mg/l
|
15 mg/l
|
Ntotal
|
20 mg/l
|
15 mg/l
|
|
Ptotal
|
6 mg/l
|
3 mg/l
|
Ptotal
|
5 mg/l
|
3 mg/l
|
|
Ptotal*
|
2 mg/l
|
1 mg/l
|
Ptot*
|
2 mg/l
|
1 mg/l
|
|
Fecal coliforms
|
20 / 100ml
|
2 / 100 ml
|
|||
Our environmentally friendly treatment systems offer:

Here are some of the latest Irish wastewater news feeds:
August BioPro Ireland is the technology leader in wastewater treatment systems. If you require an effluent treatment system to replace your septic tank please do not hesitate to contact us for a free estimate. We are available to deliver & install in the following counties; Antrim, Armagh, Carlow, Cavan, Clare, Cork, Donegal, Down, Dublin, Fermanagh, Galway, Kerry, Kildare, Kilkenny, Laois, Leitrim, Limerick, Derry, Longford, Louth, Mayo, Meath, Monaghan, Offaly, Roscommon, Sligo, Tipperary, Tyrone, Waterford, Westmeath, Wexford, Wicklow
Ireland is an island nation, and we must protect the environment as much as possible. Sewage cannot be disposed of through traditional septic tank installations anymore. Sewage Treatment.
Wastewater.
Biological wastewater sewage plants use patented technology to clean the effluent so there is no need for a septic tank or alternative means of disposal. Sewage Treatment.
Wastewater.
Septic tank replacement is paramount to helping Ireland help clean up the environment.
Sewage Treatment.
Ireland are now looking at charges to eliminate toxic septic tank installations where the effluent is not being disposed of in a manner friendly to the environment. Sewage Treatment.
Wastewater.
Septic tank installations are antiquated and are slowly harming the environment. Newer means of wastewater removal such as biological sewage treatment are now the standard for quality.
Wastewater.